Gold Member Since 2010
Audited Supplier
Shenzhen Ipopman Technology Limited

Alcohol Tester, Digital Alcohol Tester, Alcohol Tester Sensor manufacturer / supplier in China, offering Alcohol Breath Tester Manual Alcohol Tester Digital Breath Alcohol Tester, Qwerty Keyboard Remote Control, 360 Degree Car MP3, Ibreathalyzer, Breathalyzer Alcohol Tester with Key-Chain and so on.

(/ )

Supplier Homepage Product Alcohol Tester Alcohol Breath Tester Manual Alcohol Tester Digital Breath Alcohol Tester

Alcohol Breath Tester Manual Alcohol Tester Digital Breath Alcohol Tester

Purchase Qty.:
(Pieces)
100-999 1,000-2,999 3,000-4,999 5,000-9,999 10,000+
FOB Unit Price: US $4.1 US $3.65 US $3.5 US $3.3 US $3.1
Purchase Qty. (Pieces) FOB Unit Price
100-999 US $4.1
1,000-2,999 US $3.65
3,000-4,999 US $3.5
5,000-9,999 US $3.3
10,000+ US $3.1
Get Latest Price
Production Capacity: 50000/Month
Transport Package: Gift Box
Payment Terms: L/C, T/T, Paypal, Money Gram, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: I-ALT-06
  • Material: ABS
  • Dilsplay: Dual LCD Display
  • Sensor: Semiconductor Alcohol Sensor
  • Digital Display Results: (G/L Bac), (Mg/L Brac).
  • Respond Time: Within 10 Seconds.
  • Specification: CE and ROHS
  • HS Code: 902710
  • Color: White
  • Certification: CE,RoHS
  • Feature: with Time O′clock
  • Detection Range: 0.00% to 0.19% Bac /0.0 to 1.9g/L.
  • Warm-up Time: Within 10 Seconds.
  • Trademark: greattop
  • Origin: Shenzhen, China
Product Description

Features
1.       Dual LCD display.
2.       Digital alcohol test with audible alert.
3.       Range: 0.00-0.19% BAC & 0.0-1.9g/l.
4.       Quick response and resume.
5.       Auto power off.
6.       Real time & alarm timer..
7.       Temperature..
8.       Count down timer.
9.       Alcohol tester use 2× "AAA" alkaline batteries, clock use 1×AG13 button cell.

Real time
1.       In real time mode, press <ADJ> button to select 12 or 24 hour format.
2.       Press and hold <SET> button for 2 seconds to enter real time hour setting, the hour digit is flashed on the clock LCD, press <ADJ> button to adjust.
3.       Press <SET> button again to enter minute setting, the minute digit is flashed, press <ADJ> button to adjust.
4.       Press <SET> button to confirm.
Alarm time
1.       In real time mode, press <MODE> button once to enter alarm mode.
2.       Press <ADJ> button to select alarm on or off.
3.       Press and hold <SET> button for 2 seconds to enter alarm timer hour setting, the hour digit is flashed, press <ADJ> button to adjust..
4.       Press <SET> button again to enter minute setting, the minute digit if flashed, press <ADJ> to adjust.
5.       Press <SET> button to confirm.
Temperature
1.       In real time mode, press <MODE> button twice to enter temperature mode.
2.       Press <ADJ> button to select C or F format.
Count down timer
1.       In real time mode, press <MODE> button 3 times to enter timer mode.
2.       Press and hold <SET> button for 2 seconds to enter timer hour setting, the hour digit is flashed, press <ADJ> button to adjust.
3.       Press <SET> button again to enter minute setting, the minute digit flashed, press <ADJ> button to adjust.
4.       Press <SET> button to confirm.
5.       Press <ADJ> button to start countdown when the timer value is not 00:00, press <ADJ> button again to stop the timer.
When the timer count down to 00:00, the alarm will sound, then reload the timer value.

Specifications
* Sensor: advanced semiconductor oxide alcohol sensor
* Range: 0.00%-0.19% BAC (0.0-1.9g/l or 0.00-0.95mg/l BRAC)
* Test accuracy: 0.01% BAC (0.1g/l)
* Power input: 2×1.5V "AAA" alkaline battery (for alcohol tester) & 1×1.5V AG13 button cell (for clock)
* Operating time: warm up: 10s, response: <5s
* Clock accuracy: +/- 2.0 seconds/day
* Dimension: 100×37×17mm
 
Precaution
-- When after drinking, it is recommended to last after 20 minutes, it is because 20 minutes is approximately for alcohol to be absorbed into blood from the digestive organs, and residual alcohol remaining in the mouth takes this long to dissipate.
-- For accurate result, do not repeat next testing within 3 minutes after last time.
-- Do not smoke and eat for 20 minutes prior testing.
-- Do not use chemicals to clean the tester directly.
-- Do not blowing liquid into the breath pipe.
-- Do not use any excitant substances near the tester, such as paint, insecticides, alcohols.
-- Do not place the tester in the closed environment with contaminated air.
-- The result of this alcohol gives BAC for reference only, manufacturer does not to take any legal responsibility.
   

Color White
Material ABS
Certification CE,ROHS
Dilsplay Dual LCD display
Feature with time o'clock
Sensor semiconductor alcohol sensor
Detection range 0.00% to 0.19% BAC /0.0 to 1.9g/l.
Digital display results (g/l BAC), (mg/l BRAC).